Revision as of 12:03, 26 January 2021

Since the Qsys tool of the Quartus version 20.1.1 lacks some library files, this will cause users to encounter errors (See Figure 2) when regenerating their Qsys project.


Qsys regen error 01.png

Figure 1 QSYS Generation


Qsys regen error 02.png

Figure 2 QSYS Generation Error


The solution is to copy the ip_compiler_for_pci_express folder from the \System CD\Demonstrations\PCIE_DDR3 or PCIE_Fundamental to : \Your Host\<Quartus_install_path>\ip\altera\, For example : D:\intelFPGA\20.1\ip\altera\


Qsys regen error 03.png

Figure 3 ip_compiler_for_pci_express in the PCIE_DDR3 demonstration


Qsys regen error 04.png

Figure 4 paht for <Quartus_install_path>\ip\altera\